SEA LEVEL STATION MONITORING FACILITY
IntroMapStation listsStation detailsServices & FAQGLOSSCatalog
[previous station] Station at GMT [next station]
[less details] [GTS message] [show data] [show on map] [monitor]
Station metadata
Code plat2
Country Argentina
Location Mar del Plata
Status Operational
Added to the system 2010-03-31 21:22:00
Local Contact Armada Argentina Servicio de Hidrografía Naval ( Argentina )
Other Contact University of Hawaii Sea Level Center ( USA )
GLOSS core ID 192   [goto handbook]
Long-term MSL data
Latitude -38.00015278
Longitude -57.53850556
Connection GTS message
GTS message type SEPO40
GTS station code 3542B4D2
Transmit interval (min) 15
Transmit lag UTC (sec) 0
Ave. transmit delay (min) 3
Messages received (24h) 81
Messages expected (24h) 96
Sensor 1
Type of sensorrad (radar)
Sampling rate (min)1
    GTS format
Units of measurem
First value5
Samples30
Reversed orderyes
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h1304
Measurements expected1440
Performance ratio91%
Sensor 2
Type of sensorra2 (2nd radar)
Sampling rate (min)3
    GTS format
Units of measurem
First value38
Samples20
Reversed orderyes
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h465
Measurements expected480
Performance ratio97%
Sensor 3
Type of sensorenc (float sensor with encoder)
Sampling rate (min)5
    GTS format
Units of measurem
First value61
Samples12
Reversed orderyes
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h270
Measurements expected288
Performance ratio94%
Sensor 4
Type of sensorsw1 (1st switch)
Sampling rate (min)60
    GTS format
Units of measuremin
First value76
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h78
Measurements expected24
Performance ratio325%
Sensor 5
Type of sensorsw2 (2nd switch)
Sampling rate (min)60
    GTS format
Units of measuremin
First value80
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h78
Measurements expected24
Performance ratio325%
Sensor 6
Type of sensorbat (battery)
Sampling rate (min)15
    GTS format
Units of measureV
First value84
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-03-29 15:34:00
Last data received at2024-03-29 15:38:03
Measurements received in 24h78
Measurements expected96
Performance ratio81%
Period SignalsData

12h
day
7 days
30 days
rad (radar)
ra2 (2nd radar)
enc (float sensor with encoder)
Remove outliers
Remove spikes
Relative levels = signal - median over selected period
Absolute levels = as received
Offset signals = relative levels + offset
Show switch data
Show battery voltage
Tip:use left icons to zoom & scroll